Stand Regulation Visuals

EBACE exhibitors, exhibitor-appointed contractors (EAC) and stand builders should review the following booth visuals and read the Indoor Exhibitor Rules to ensure their stands are in compliance with show rules.

All exhibitors in raw space, including inline raw space, must submit complete stand drawings online via the Stand Drawing Submission Portal to EBACE show management for approval by 19 March 2021.

Review Stand Drawing Approval for the full list of required elements and contact information.

Inline Stand – Shell Scheme Space

Floor Plan View: Inline Stand - Shell Scheme SpaceInline shell scheme stands contain one or more 3m-by-3m units in a straight line with stands on either side and behind their back walls.

Maximum height:Exhibit elements – 2.5m (8 ft)
Company name header – 3.05m (10 ft)
Stand Drawings:Not Required
Hanging Signs:Not Permitted
Lighting Trusses:Not Permitted
Additional information:
  • All stand elements must be ground supported.
  • Solid white back wall and side wall panels dimensions: 1m (3.28 ft)  x 2.5m (8ft)
  • White metal crossbars to affix fascia name board and spotlights.
  • Exhibitors must provide flooring for the entirety of their exhibit space.
Corner Shell Scheme Unit
Corner Shell Scheme Unit

 

Interior Shell Scheme Unit

Interior Shell Scheme Unit

Inline Stand – Raw Space

Floor Plan View: Inline Stand - Raw SpaceInline raw space is perfect for exhibitors who are building custom stands and have their own wall structures. Inline raw space is defined as a narrow stand space comprised of one or more 3m-by-3m units in a straight line. Inline raw space does not include shell-scheme walls.

Maximum height:Exhibit elements – 2.5m (8 ft)
Company name header – 3.05m (10 ft)
Stand Drawings:Required by 19 March 2021
Hanging Signs:Not Permitted
Lighting Trusses:Not Permitted
Additional information:
  • All stand elements must be ground supported.
  • Inline raw exhibit space does not have shell scheme hardwalls.
  • All hardwalls must be finished.
  • No identification of any kind is allowed on a back wall that adjoins another exhibitor. This includes the company logo.
  • Inline raw space exhibitors may have shell scheme stands next to and behind them.
  • Exhibitors must provide flooring for the entirety of their stand space.
Inline Stand - Raw Space
Inline Stand – Raw Space

Main Aisle Island Stand

Floor Plan View: Main Aisle Island StandA main aisle island stand is exhibit space that is a minimum of 36 sqm, is surrounded by aisles on all four sides and is located on the red main aisles on the floor plan. These locations are highlighted in orange on the exhibitor view of the floor plan.

Maximum height:4.6m (15 ft)
Stand Drawings:Required by 19 March 2021
Hanging Signs:Not Permitted
Lighting Trusses:
  • Lighting trusses are permitted if they are included on the stand drawings, do not exceed 9.1m (30 ft) in height, and are fully contained within the exhibitor’s purchased exhibit space./strong>
  • Lights must be directed to the interior boundaries of the exhibitor’s purchased exhibit space.
  • Bulbs: Halogen or LED.
  • Lighting, including lamps, strobe, gobo flashing and rotating lighting, may not interfere with neighboring stands.
Additional information:
  • All back and side walls must be finished.
  • May have no more than 50% hard walls – regardless of stand size.
    Note: Glass counts as a hard wall.
  • All stand elements must be ground supported.
  • A maximum of 4 support cables is permitted, and must be included in stand drawing submission and approved by EBACE show management in advance.
  • If rigging is needed for install only, it must be noted on stand drawing submission and approved by EBACE show management in advance.
  • Exhibitors must provide flooring for the entirety of their stand space. Stand drawings will not be reviewed until all required elements, EAC application/contract and EAC certificate of insurance have been received.
Island Stand
Island Stand

Non-Main Aisle Island Stand

Floor Plan View: Non-Main Aisle Island StandA non-main aisle island stand is exhibit space that is a minimum of 36 sqm, is surrounded by aisles on all four sides and is not located on the designated main aisles.

Maximum height:6.1m (20 ft)
Stand Drawings:Required by 19 March 2021
Hanging Signs:Not Permitted
Lighting Trusses:
  • Lighting trusses are permitted if they are included on the stand drawings, do not exceed 9.1m (30 ft) in height, and are fully contained within the exhibitor’s purchased exhibit space.>
  • Lights must be directed to the interior boundaries of the exhibitor’s purchased exhibit space.
  • Bulbs: Halogen or LED.Lighting, including lamps, strobe, gobo flashing and rotating lighting, may not interfere with neighboring stands.
Additional information:
  • All back and side walls must be finished.May have no more than 50% hard walls – regardless of stand size.
    Note: Glass counts as a hard wall.
  • All stand elements must be ground supported.
  • If rigging is needed for install only, it must be noted on stand drawing submission and approved by EBACE show management in advance.
  • Exhibitors must provide flooring for the entirety of their stand space.
  • Stand drawings will not be reviewed until all required elements, EAC application/contract and EAC certificate of insurance have been received.
  • Note: Exhibitors with multi-level exhibitss or rigging, regardless of size, must submit a copy of a sealed and scaled floor plan, with font and side elevations, to EBACE show management and Palexpo. Review Stand Drawing Approval for more information.
Island Stand
Island Stand

Peninsula Stand

Floor Plan View: eninsula Stand<A peninsula stand is an exhibit space that is a minimum of 36 sqm, is exposed to aisles on three sides and shares a common back wall with another exhibitor.

Maximum height:Non-main aisle – 6.1m (20 ft) Main aisles – 4.6m (15 ft)
Stand Drawings:Required by 19 March 2021
Hanging Signs:Not Permitted
Lighting Trusses:
  • Lighting trusses are permitted if they are included on the stand drawings, do not exceed 9.1m (30 ft) in height, and are fully contained within the exhibitor’s purchased exhibit space.
  • Lights must be directed to the interior boundaries of the exhibitor’s purchased exhibit space.
  • Bulbs: Halogen or LED.Lighting, including lamps, strobe, gobo flashing and rotating lighting, may not interfere with neighboring stands.
Additional requirements:
  • All back and side walls must be finished.
  • May have no more than 50% hard walls — regardless of stand size.
    Note: Glass counts as a hard wall.
  • All stand elements must be ground supported.
  • A maximum of 4 support cables is permitted, and must be included in stand drawing submission and approved by EBACE show management in advance.
  • If rigging is needed for install only, it must be noted on stand drawing submission and approved by EBACE show management in advance.
  • Exhibitors must provide flooring for the entirety of their stand space.
  • Stand drawings will not be reviewed until all required elements, EAC application/contract and EAC certificate of insurance have been received.
  • Note: Exhibitors with multi-level exhibits or rigging, regardless of size, must submit a copy of a sealed and scaled floor plan, with font and side elevations, to EBACE show management and Palexpo. Review Stand Drawing Approval for more information.
Peninsula Stand
Island Stand

Perimeter Island Stand

Floor Plan View: Perimeter Island StandPerimeter stands are located along the perimeter of the exhibit hall and are highlighted in green on the exhibitor view of the floor plan.

Maximum height:9.1m (30 ft)
Stand Drawings:Required by 19 March 2021
Hanging Signs:Permitted to a maximum height of 9.1m (30 ft)
Lighting Trusses:
  • Lighting trusses are permitted if they are included on the stand drawings, do not exceed 9.1m (30 ft) in height, and are fully contained within the exhibitor’s purchased exhibit space.
  • Lights must be directed to the interior boundaries of the exhibitor’s purchased exhibit space.
  • Bulbs: Halogen or LED.
  • Lighting, including lamps, strobe, gobo flashing and rotating lighting, may not interfere with neighboring stands.
Additional requirements:
  • All side walls must be finished.Exhibitors must provide flooring for the entirety of their stand space.
  • Stand drawings will not be reviewed until all required elements, EAC application/contract and EAC certificate of insurance have been received.
  • Note: Exhibitors with multi-level exhibits or rigging, regardless of size, must submit a copy of a sealed and scaled floor plan, with font and side elevations, to EBACE show management and Palexpo. Review Stand Drawing Approval for more information.
Perimeter Island Stand
Perimeter Island Stand

Stand Drawing Approval

All exhibitors in raw space, including inline raw space, must submit complete stand drawings online via the Stand Drawing Submission Portal to EBACE show management for approval by 19 March 2021. Review the Stand Configuration Rules. 

Exhibitors must submit complete stand drawings for approval even if they are using the same exhibit as in previous years.

Drawings will not be reviewed until all required elements, as well as the EAC contract and EAC certificate of insurance, are provided.

All drawings must be submitted to both EBACE show management and to Palexpo.

To submit drawings to EBACE show management, use the Stand Drawing Submission Portal. This portal will be available in the coming months.

To submit drawings to Palexpo, contact:

Palexpo
Claudine Fischer
Email: [email protected]
Telephone: +41 (0) 22761 11 43

For more information, please contact EBACE management:

Sarah Kurusz
Manager, Exhibits
Email: [email protected] 
Tel: +1 (202) 783-9289

Maureen Cameron
Director, Exhibits
Email: [email protected] 
Tel: +1 (202) 783-9453

Stand drawings must include the following elements:

  • Event name: EBACE2021
  • Exhibitor name and stand number
  • Rendering packet, including views of all four sides and an overhead view
  • Complete technical drawings with the following information:
    • Stand dimensions (heights, widths and lengths of hard walls, including glass)
    • Maximum height of stand
    • Orientation (label surrounding stand numbers)
    • Any rigging or safety points (if applicable)
      Note: a maximum of 4 safety points are permitted on non-perimeter stands.
    • Hanging signs, if applicable (permitted in perimeter locations only)
    • Truss or overhead lighting.
      Note: Lighting trusses must fit completely within purchased exhibit space and cannot extend into or over the aisle.

Multi-level and Covered Exhibits:

  • Exhibitors with multi-level and covered stands are required to receive approval from both EBACE show management and Palexpo.
  • Multi-level and covered stand submissions must include the following in addition to the items listed above:
    • Maximum number of occupants allowed
    • Structural engineer’s stamp certifying that the platform can bear the maximum occupant load
    • Rise and run/tread of steps/stairs
    • Drawings for tents, awnings, and canopies with detailed plans showing size, height, location, anchoring areas and certification that the material is flame retardant
  • Copies of sealed and scaled floor plans, with front and side elevations.